The documents to name when you specify GFRP.

Name the document that matches the work. Material: IS 18256:2023. Test methods: IS 18255. Roads and bridges: IRC:137-2022. A US contract names ASTM D7957 and ACI 440.1.

What to write on the drawing

  • GFRP, solid round bar, ribbed
  • Diameter, from 6 mm to 25 mm
  • Straight bar to 12 m, or coil for 6 and 8 mm
  • IS 18256:2023, and IRC:137-2022 on a highway

GFRP rebar material composition

Continuous glass fibre in a cured resin, formed as a solid round bar with a helical rib. The bar is glass, not basalt and not carbon.

Mechanical properties

Tensile strength, elastic modulus and bond are design properties, taken from the standard named on the drawing.

Diameter and supply

Diameters on the product table are 6, 8, 10, 12, 16, 20 and 25 mm. Dimensional tolerances follow the standard named on the drawing.

Testing methods and standards

IS 18255 covers the test methods. Confirm the papers that can travel with the order.

IS 18256:2023

Material standard

Name this on a material specification for solid round GFRP bars. It covers materials, the ribbed surface and minimum performance.

IS 18255

Test methods

The companion to IS 18256. Tensile tests, bond tests and durability tests refer back to it.

IRC:137-2022

Roads and bridges

Indian Roads Congress guidelines for GFRP reinforcement on roads, highways and bridges. A highway specification should name this document, not IS 456 with the bar substituted.

ASTM D7957

US material standard

The US material standard for solid round GFRP bars. Relevant when a contract is written to ASTM rather than to Indian standards.

ACI 440.1

US design guide

The US design guide for concrete reinforced with FRP bars. Often used when an Indian FRP design needs a worked method.

BIS indicates that IS 18256 bars are intended first for lower-risk parts of a structure, unless the engineer approves the part. For roads and bridges, IRC:137 is the document to use. See GFRP for bridges and the comparison with TMT.

Send your specification.

If the tender names a standard or a test, include it with the bar list so the reply can match the enquiry.